80kVA UPS 64kw Three Phase Low Frequency

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $4,100-4,300/ Piece
Port: Shenzhen, China
Production Capacity: 1000PCS/Months
Payment Terms: L/C, T/T, Western Union, Paypal
Phase: Three Phase
Type: On-line
Protection: Over Voltage / Short Circuit
Application: Industry
Standby Time: Long-acting Machine
Standby UPS: Sine Wave Output UPS

You Might Also Like

Loading...

Basic Info

Model NO.: GL33 80kva
Output Capacity: Large Type
Equipment Mode: Centralized Model
Features: Isolated Transformer
Input Voltage: 380V400/415VAC
Power Efficiency: 80%
Transfer Time: 0 Ms
Battery Type: Sealed Lead Acid Maintenance-Free Battery
Warranty: 12 Months
Trademark: STCB/Neutral
Transport Package: Cartons
Origin: Guangzhou Shenzhen
HS Code: 8504402000

Product Description

80kVA UPS 64kw Three Phase Low Frequency
 
Main Features:
1. Online double-conversion
2. DSP technology guarantees high reliability
3. True galvanic isolation transformer design
4. Control designed to withstand all kinds of loads
5. Intelligent battery management to prolong battery lifecycle
6. Redundant fan design and independent ventilation enhance durable operation under harsh environment
7. Adjustable battery numbers
8. Accept dual-mains input
9. Parallel operation with up to 4 units (option)
10.Variety of communication options available

Product discription:
The On-Line-Series is an uninterruptible power supply incorporating
double-converter technology. It provides perfect protection specifically for
strict load.
The double-converter principle eliminates all mains power
disturbances. A rectifier converts the alternating current from the socket
outlet to direct current. This direct current charges the batteries and powers
the inverter.
In the event of power failure, the maintenance-free batteries
power the inverter. Thus the inverter generates a sine wave AC power,
which permanently supplies the loads.
 
Designed with the proven on-line, double conversion architecture, this
series of UPS offers the greatest degree of availability in power protection
and provides continuous high-quality AC power to connect strict load,
especially for the basic equipments in some areas as: finance,
communication, government, traffic, manufacture, education and so on.
 
Additionally The UPS provides abundant interfaces such as RS232, SNMP, AS400, and RS485 for supervision and configure.

Specification:
MODELGL33
10K
GL33
20K
GL33
30K
GL33
40K
GL33
60K
GL33
80K
CAPACITY10KVA
8KW
20KVA
16KW
30KVA
24KW
40KVA
/32KW
60KVA
48KW
80KVA
64KW
INPUT
Nominal Voltage3 x 380VAC/400VAC (3Ph + N)
Voltage Range305VAC ~ 460VAC
Frequency46-54Hz or 56-64Hz
INVERTER
Nominal Voltage3 x 380VAC/400VAC (3Ph + N)
PrecisionStationary: ±1%
 Transitory: ±5% (load variations 100-0-100%)
Frequency50/60 Hz synchronised ±1 %
              With mains absent ±0.1 Hz
Max. Synchronisation Speed±1 Hz/s
WaveformPure Sine wave
Total Harmonic 
Distortion (THDv)
<2% (Linear Load)
<5% (Non-linear Load)
Phase Displacement120º ±1% (balanced load)
120º ±2% (imbalances 50% of the load)
Dynamic Recovery Time1 cycle at 98 % of the static value
Admissible Overload110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor3:1
Admissible Power Factor0.6~1 (inductive or capacitive)
Imbalance Output Voltage<1% @ 100% Unbalanced Load
Current LimitHigh overload, short-circuit: RMS Voltage Limit
 High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
TypeSolid state
Voltage3 x 380VAC/400VAC (3Ph + N)
Frequency50/60 Hz
Activation CriterionMicroprocessor control
Transfer TimeZero
Admissible Overload150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to BypassImmediate, for overloads above 160%
RetransferAutomatic after alarm clear
MAINTENANCE BYPASS
TypeWithout interruption
Voltage3 x 400V (3Ph + N)
Frequency50/60 Hz
Overall 
Efficiency
Line Mode90%91%92%93%
Battery Mode90%91%93%93%
BATTERY & CHARGER
Battery Type and Numbers 16 pcs32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage192 VDC384 VDC (Based on 32pcs batteries)
Charging MethodCC/CV
Precision±1%
Charging CurrentMax.: 40 A
Charging Voltage216 VDC432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions(mm)656*405*817656*405*941840*432*1140975*554*1286
Net Weight (Kg)180205295330451519